New Micro800 Lessons on Plug-in Analog Inputs, Scaling, and more

Our Five Star rated Micro800 course, Nano Basics, receives new lessons on using Plug-In I/O, Scaling, and more! In the first new lesson, students learn...

Math with Mixed Data Types in the Micro800

While Rockwell's Micro800 line of programmable controllers does include support for instructions you won't find in RSLogix, it's lacking one big feature that many...

The Micro800 Timer On Off Instruction

Rockwell's Micro800 line of programmable controllers include support for a few instructions you won't find in RSLogix. In today's article we'll discuss one of those instructions,...

The Micro800 Reverse Coil Instruction

Rockwell's Micro800 line of programmable controllers include support for some instructions you won't find in RSLogix. In today's article we'll discuss one of those instructions, the...

Downloading Programs to a Micro800

In today's article I'll walk you through how to download a program to a Micro800 using Connected Components Workbench version 10. Preface: If you need a...

Micro800 Program Structure: How it differs from other A-B PLCs

While Rockwell's Micro800 family of low cost programmable controllers have appealing price points, one look at the programming software is often enough to keep many Logix...

Micro800 IO Tags and Aliasing

Rockwell's Micro800 family of low cost programmable controllers have very appealing price points. But when it comes to usability, many of us have been reluctant...

Setup RSLinx Ethernet Comms to the Micro800

To program Rockwell's Micro820 and Micro850 over Ethernet you first need to know how to setup RSLinx Classic's Ethernet drivers, and in today's article...

How to "Ping" a PLC

PLCs of all shapes and sizes now come with Ethernet communications built-in. And one of the easiest ways to insure you have network connectivity between...

Assign a Micro800 an Ethernet Address

Rockwell's Micro820 and Micro850 both have built-on Ethernet communication ports, and in today's article I'll show you two ways to assign these ports an...

Setup Micro800 USB Comms

Rockwell's Micro830 and 850 have convenient USB programming ports built in, and an optional USB programming port can be added to Micro810 and 820. In...

New affordable Micro800 training from The Automation Blog!

For many of us who've spent years (or decades) programming Allen-Bradley PLCs, the thought of learning a new PLC line or brand can bring on a...

Where can you download a free copy of Connected Components Workbench?

So you've heard about Rockwell's new line of low cost Micro PLCs, and now want to get your hands on the free software to...
RSLogix-MIcro-Starter-Splash-Fi

What's new in RSLogix 500 and Micro v11

RSLogix 500 and RSLogix Micro version 11 is out, and in today's article we'll take a look at what's new in this release: UPDATE: My MicroLogix "Five...

What's New in Connected Components Workbench 10?

Connected Components Workbench (CCW) version 10 is out and in today's article we'll take a look at what's new and different in this release: UPDATE: My...

I want to learn A-B PLC's, which model should I get?

This is a common question I get here on the blog and from my students at TheAutomationSchool.com. And while Rockwell has released many different platforms since...

How to setup RSLinx for PLC-5 and SLC-500 on Data Highway Plus

So you need to know how to setup RSLinx Classic to communicate via USB over Data Highway Plus to an Allen-Bradley PLC-5 or SLC-5/04? Well you're in...

How to setup RSLinx and download to a PLC-5 via Serial

So you need to know how to setup RSLinx Classic to communicate over serial with an Allen-Bradley PLC-5 so you can download or go online...

How to setup RSLinx and download to a SLC-500 via DH-485

So you need to know how to setup RSLinx Classic to communicate over DH-485 to an Allen-Bradley SLC-500 so you can download or go online...

How to setup RSLinx and download to a SLC-500 via Serial

So you need to know how to setup RSLinx Classic to communicate over serial with an Allen-Bradley SLC-500 so you can download or go online with...

How to setup RSLinx and download to a MicroLogix 1400

So you need to know how to setup RSLinx Classic to communicate to an Allen-Bradley MicroLogix 1400 using Ethernet in order to download or go...

How to setup RSLinx comms and connect to a MicroLogix 1100

So you need to know how to setup RSLinx Classic to communicate to an Allen-Bradley MicroLogix 1100 using Ethernet in order to download or go...

How to setup RSLinx comms and connect to a MicroLogix 1200

So you need to know how to setup RSLinx Classic to communicate to an Allen-Bradley MicroLogix 1200 in order to download or go online with...

How to setup RSLinx comms and connect to a MicroLogix 1500

So you need to know how to setup RSLinx Classic to communicate to an Allen-Bradley MicroLogix 1500 in order to download or go online with...

How to setup RSLinx comms and connect to a MicroLogix 1000

So you need to know how to setup RSLinx Classic to communicate to an Allen-Bradley MicroLogix 1000 in order to download or go online with...

Do you really need RSLogix 500 to program a MicroLogix?

Over the last few months I've received several messages asking what the correct software is to program the MicroLogix line of programmable controllers. This confusion surprises...

USB to Data Highway Plus using the ANC-120e, a lower cost alternative to the...

In today's episode of The Automation Podcast I take a look at the ANC-120e USB to Data Highway Plus converter from Automation Networks. Now you may...

How to download free Allen-Bradley Sample Code, Programs and AOIs

One of the topics I like to cover in my training courses is how users can get (and use) free sample code, programs, and...

How to download RSLogix Micro, RSLinx, and Emulate for free (Fall 2016)

UPDATE: As of November 2017 this procedure still works as long as you follow all the steps, including Step 5. I commend Rockwell on their efforts...

MicroLogix 1000 vs. 1100 Part Two: Data Files

While the MicroLogix 1000 is the least expensive RSLogix based PLC from Rockwell Automation (starting around $150,) it's also the most limited. That in mind,...