ViewSE on Ethernet to PLCs on Data Highway Plus via Logix Gateway (S38)

In this week's episode of The Automation Show, I cover how to setup FactoryTalk ViewSE and RSLinx Classic Lite on Ethernet to communicate to PLCs on Data Highway Plus through a Logix Gateway: For more information, check out the "Show...

Converting ControlNet I/O to EtherNet I/O

If you have had ControlLogix systems running in your facility for any amount of time, chances are they contain ControlNet communication modules for the communication between processor chassis and their controlled remote I/O chassis as well as a myriad...

Getting CIP Data from your Stratix Switch

Have you ever used or thought of using your HMI as a network monitoring tool? What if your HMI system was used for more than just an operational tool? What if it can also help you, as a control system...

Setting up a 1783-ETAP

If you are contemplating using a Device Level Ring (DLR) topology in your control system networks, an important device in that network is the EtherNet Tap (ETAP). If the remote devices in your DLR network will require fiber, the ETAP...

Device Level Ring: Adding a Remote I/O Chassis

I first began using ControlLogix in 2001, back when the software and firmware were both at version 7. In those early days it wasn't so easy to add a new remote I/O Chassis to an existing ControlLogix system as most...

Using The 1783-NATR To Bridge Networks

With small control teams managing already large and increasingly growing control systems, an opportunity that I have encountered is the need to remotely access programmable logic controllers for various reasons, including troubleshooting as well as performing administration tasks. Often, the...

ControlLogix Reading Data From CompactLogix, SLC-500, MicroLogix over Ethernet (Video S29)

In this week's episode of The Automation Show, I cover how to use the MSG (Message) Instruction in the ControlLogix to read data from CompactLogix, SLC-500, and MicroLogix over Ethernet: For more information, check out the "Show Notes" located below...

How to add Ethernet Flex I/O to ControlLogix (Article & Video, TAS 21)

In today's article (and video) I walk through how to add Ethernet Flex I/O to a ControlLogix System: Step 1) To start, open your RSLogix 5000 or Studio 5000 project and find your Ethernet communications module under I/O Configuration. Once...

How To Add Ethernet Point I/O To ControlLogix (Video, TAS 17)

In this week's episode of The Automation Show, we take a look at how you add Ethernet Point I/O to a ControlLogix system: For more information, check out the "Show Notes" located below the video. [vimeo 366838759 w=750 h=420] The Automation Show,...

How To Set The IP Address Of A New Siemens S7-1200 PLC (Video, TAS...

In this week's episode of The Automation Show, we take a look at how you set the IP Address of a new Siemens S7-1200: For more information, check out the "Show Notes" located below the video. [vimeo 366837103 w=750 h=420] The Automation...