Data Highway Plus

Prosoft EtherNet/IP to DH+ Gateway (P147)

Today my guest is Dennis Gonzalez of Prosoft who details the capabilities of their AN-X4-AB-DHRIO Ethernet/IP to DH+ Gateway in Episode 147 of The Automation Podcast. For more information, check out the "Show Notes" located below the video. Watch the Podcast: [vimeo 812931146 w=750 h=420] The Automation Podcast is also available on most...

FTLinx, RSLinx Enterprise – DH+ / Data Highway Plus Timeouts (Q&A)

In this edition of "Community Q & A" (formerly "Insight's Inbox",) I discuss with one of our community members at automation.locals.com what might be causing one of his Data Highway Plus devices to keep timing out. Note: To see a list of all our Data Highway Plus videos and articles,...

ViewSE on Ethernet to PLCs on Data Highway Plus via Logix Gateway (S38)

In this week's episode of The Automation Show, I cover how to setup FactoryTalk ViewSE and RSLinx Classic Lite on Ethernet to communicate to PLCs on Data Highway Plus through a Logix Gateway: For more information, check out the "Show Notes" located below the video.  The Automation Show, Episode 38 Show...

FTLinx, RSLinx Enterprise, ViewME – DH+ / Data Highway Plus to ControlLogix, SLC-5/04, & PLC-5 (S35)

In this week's episode of The Automation Show, I cover how to use View Studio to create and download a PanelView Plus program to read data from a ControlLogix, SLC-5/04 and PLC-5 over a Data Highway Plus network: For more information, check out the "Show Notes" located below the video.  The...

PanelView Standard – Communicate over Data Highway Plus (DHP, DH+) or DH-485 to CompactLogix, ControlLogix(S33)

In this week's episode of The Automation Show, I cover how to use PanelBuilder 32 to create and download a PanelView Standard program to read data from a CompactLogix or ControlLogix over Data Highway Plus or Data Highway 485: For more information, check out the "Show Notes" located below the...

PanelView Standard – Data Highway Plus (DHP, DH+) Communications to SLC-5/04 and PLC-5 (S32)

In this week's episode of The Automation Show, I cover how to use PanelBuilder 32 to create and download a PanelView Standard program to read data from a SLC-5/04 and PLC-5 over a Data Highway Plus network: For more information, check out the "Show Notes" located below the video.  The Automation...

Message (MSG) – ControlLogix Reading Data Over Data Highway Plus (DH+, DHP) from PLC-5, SLC-500 (S27)

In this week's episode of The Automation Show, I cover how you can use the MSG (Message) Instruction in the ControlLogix to read data from the PLC-5 and SLC-500 over a Data Highway Plus network: For more information, check out the "Show Notes" located below the video.  The Automation Show, Episode...

Data Highway Plus to Ethernet (S02)

In today's episode of The Automation Show, I unbox and setup an ANC-100E Data Highway Plus to Ethernet bridge from Automation Networks. For more information about the show (and how you could win an ANC-100E) check out the "Show Notes" located below the video. [vimeo 368588909 w=750 h=420] The Automation Show, Episode 2...

USB to Data Highway Plus (DHP, DH+) – Setup RSLinx with ANC-120e and Download to PLC-5 and SLC-500 using RSLogix

So you need to know how to setup RSLinx Classic to communicate via USB over Data Highway Plus to an Allen-Bradley PLC-5 or SLC-5/04? Well you're in luck as in today's article I'll walk you step to setup through how to setup RSLinx as well as the ANC-120e USB to DH+ cable...

Sample Code – Setup and Download Demo Programs to A-B PLCs (P36)

Watch as I setup a PLC-5, SLC-5/05 & 5/04, MicroLogix 1100 & 1400, ControlLogix L61, L55 & L1, a FlexLogix and CompactLogix L1 in Episode 36 of The Automation Podcast. Watch the Podcast: [vimeo 365838779 w=750 h=420] Listen to the Podcast:

USB to Data Highway Plus (DHP, DH+) – Setup RSLinx with ANC-120e and Download to PLC-5 and SLC-500 using RSLogix (M3E19)

Learn how to setup USB to Data Highway Plus (DH+) communications to an A-B SLC-5/04 or PLC-5 in Episode 19 of The Automation Minute Season 3: [vimeo 468320895 w=640 h=360] If you've found this video helpful, checkout my training courses here. Check out our Video Collection #1 here, which includes the first...

USB To Data Highway Plus (DHP, DH+) – Using the ANC-120e, a lower cost alternative to the 1784-U2DHP

In today's episode of The Automation Podcast I take a look at the ANC-120e USB to Data Highway Plus converter from Automation Networks. Now you may be asking yourself why the folks over at Automation Networks would release a USB to DH+ converter when Rockwell already makes the 1784-U2DHP? Well if you...

USB To Data Highway Plus (DHP, DH+) – First Look and Use of the ANC-120e (P35)

Learn how to connect your PC to Data Highway Plus using USB and a much lower cost alternative to the 1784-U2DHP, the ANC-120e from Automation Networks, in Episode 35 of The Automation Podcast. Watch the Podcast: [vimeo 365837699 w=750 h=420] Listen to the Podcast: